Eaton Tripp Lite Series SmartOnline 3000VA 2700W 120V Double-Conversion UPS - 5 Outlets, Extended Run, Network Card Option, LCD, USB, DB9, Tower - Battery Backup

Tripp Lite by Eaton
SU3000XLCD
037332158871
Product Overview
  • Tower
  • 3 Hour Recharge
  • 5.7 Minute Stand-by
  • 100 V AC, 110 V AC, 115 V AC, 120 V AC, 127 V AC Input
  • 100 V AC, 110 V AC, 115 V AC, 120 V AC, 127 V AC Output
  • 8 x NEMA 5-15/20R, 1 x NEMA L5-30R

Double-Conversion UPS Protects Equipment Against Damage, Downtime and Data Loss
This on-line double-conversion UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC. Constant on-line operation isolates sensitive equipment from power problems on the AC line. The SmartOnline® SU3000XLCD provides the highest level of power protection and battery backup for education, healthcare, military, government and other mission-critical IT applications where space is limited, but premium power reliability is essential.

Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Zero transfer time between on-line and battery modes maintains continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP96V, sold separately).

Optional Network Management Card Allows Remote Access 24/7
The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.

NEMA Outlets Protect Your Connected Components
One L5-30R and four 5-20R outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. The 5-20R outlets are grouped into two load banks that let you shed non-critical loads to extend runtime for critical loads.

Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.

Clear LCD Interface Keeps You Informed at a Glance
The menu-driven front-panel LCD provides detailed alarms and notifications to help diagnose any issues. It provides system status, event logs, battery and power module status, usage analytics, serial number, firmware update info and more. Audible alarms can be disabled through the front menu when the UPS goes to battery power.

Advanced Communications Ports Allow for Automatic Saves and Shutdowns
RS-232 and USB ports connect to a device for a variety of communication options (cables are included). A dry-contact relay port can be programmed through the LCD to provide reliable communications to automation and industrial components. The RPO/ROO port permits emergency shutdown or remote restart of all connected equipment.

ManufacturerTripp Lite by Eaton
Manufacturer Part NumberSU3000XLCD
Manufacturer Website Addresshttps://tripplite.eaton.com/
Brand NameTripp Lite by Eaton
Product LineSmartOnline
Product ModelSU3000XLCD
Product NameSmartOnline SU3000XLCD 3000VA Tower UPS
Marketing InformationDouble-Conversion UPS Protects Equipment Against Damage, Downtime and Data Loss
This on-line double-conversion UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC. Constant on-line operation isolates sensitive equipment from power problems on the AC line. The SmartOnline® SU3000XLCD provides the highest level of power protection and battery backup for education, healthcare, military, government and other mission-critical IT applications where space is limited, but premium power reliability is essential.

Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Zero transfer time between on-line and battery modes maintains continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP96V, sold separately).

Optional Network Management Card Allows Remote Access 24/7
The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.

NEMA Outlets Protect Your Connected Components
One L5-30R and four 5-20R outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. The 5-20R outlets are grouped into two load banks that let you shed non-critical loads to extend runtime for critical loads.

Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.

Clear LCD Interface Keeps You Informed at a Glance
The menu-driven front-panel LCD provides detailed alarms and notifications to help diagnose any issues. It provides system status, event logs, battery and power module status, usage analytics, serial number, firmware update info and more. Audible alarms can be disabled through the front menu when the UPS goes to battery power.

Advanced Communications Ports Allow for Automatic Saves and Shutdowns
RS-232 and USB ports connect to a device for a variety of communication options (cables are included). A dry-contact relay port can be programmed through the LCD to provide reliable communications to automation and industrial components. The RPO/ROO port permits emergency shutdown or remote restart of all connected equipment.

Product TypeDouble Conversion Online UPS
Plug/Connector TypeNEMA 5-15P
Receptacle TypeNEMA L5-30R
Receptacle TypeNEMA 5-20R
Receptacle Detail1 x NEMA L5-30R
Receptacle Detail4 x NEMA 5-20R
Overload ProtectionYes
Transfer Time0 ns
PhaseSingle Phase
Application/UsageGovernment
Application/UsageEducation
Application/UsageHealthcare
Application/UsageMission Critical Equipment
Application/UsageMilitary
Application/UsageIT Equipment
Load Capacity (VA)3000 VA
Load Capacity (Watt)2700 W
Input Voltage120 V AC
Output Voltage110 V AC
Output Voltage120 V AC
Output Voltage100 V AC
Output Frequency60 Hz
Waveform TypePure Sine Wave
Surge Energy Rating190 J
Input Power Factor0.99
Output Power Factor0.9
DisplayLCD
Network ManagementSNMP
AlarmLow Battery
AlarmPower Failure
AlarmUPS StartUp
AlarmRemote Shutdown
AlarmUPS Fault
AlarmOverload
Status IndicatorsFront panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options
Serial PortYes
USBYes
DC System Voltage96 V DC
Battery CharacteristicsValve-regulated
Battery ChemistryLead Acid
Backup/Run Time (Full Load)5.70 Minute
Backup/Run Time (Half Load)16.70 Minute
Hot SwappableYes
Typical Battery Recharge Time3 Hour
Replaceable BatteryYes
Maximum Operating Elevation9842.52 ft
Storage Temperature32°F (0°C) - 104°F (40°C)
Minimum Operating Temperature32°F (0°C)
Maximum Operating Temperature104°F (40°C)
Sound Emission52 dB
Height13.6"
Width8.4"
Depth16.2"
Form FactorTower
Weight (Approximate)73.64 lb
Package Contents
  • SmartOnline SU3000XLCD 3000VA Tower UPS
  • USB cable
  • DB9 cable
  • Quick Start Guide
  • Software IncludedPowerAlert Software
    Environmentally FriendlyYes
    Environmental CertificationREACH
    Environmental CertificationRoHS
    Country of OriginChina
    Limited Warranty2 Year
    General Information
    ManufacturerTripp Lite by Eaton
    Manufacturer Part NumberSU3000XLCD
    Manufacturer Website Addresshttps://tripplite.eaton.com/
    Brand NameTripp Lite by Eaton
    Product LineSmartOnline
    Product ModelSU3000XLCD
    Product NameSmartOnline SU3000XLCD 3000VA Tower UPS
    Marketing InformationDouble-Conversion UPS Protects Equipment Against Damage, Downtime and Data Loss
    This on-line double-conversion UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC. Constant on-line operation isolates sensitive equipment from power problems on the AC line. The SmartOnline® SU3000XLCD provides the highest level of power protection and battery backup for education, healthcare, military, government and other mission-critical IT applications where space is limited, but premium power reliability is essential.

    Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
    The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Zero transfer time between on-line and battery modes maintains continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP96V, sold separately).

    Optional Network Management Card Allows Remote Access 24/7
    The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.

    NEMA Outlets Protect Your Connected Components
    One L5-30R and four 5-20R outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. The 5-20R outlets are grouped into two load banks that let you shed non-critical loads to extend runtime for critical loads.

    Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
    This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.

    Clear LCD Interface Keeps You Informed at a Glance
    The menu-driven front-panel LCD provides detailed alarms and notifications to help diagnose any issues. It provides system status, event logs, battery and power module status, usage analytics, serial number, firmware update info and more. Audible alarms can be disabled through the front menu when the UPS goes to battery power.

    Advanced Communications Ports Allow for Automatic Saves and Shutdowns
    RS-232 and USB ports connect to a device for a variety of communication options (cables are included). A dry-contact relay port can be programmed through the LCD to provide reliable communications to automation and industrial components. The RPO/ROO port permits emergency shutdown or remote restart of all connected equipment.

    Product TypeDouble Conversion Online UPS
    Technical Information
    Plug/Connector TypeNEMA 5-15P
    Receptacle TypeNEMA L5-30R
    Receptacle TypeNEMA 5-20R
    Receptacle Detail1 x NEMA L5-30R
    Receptacle Detail4 x NEMA 5-20R
    Overload ProtectionYes
    Bypass SwitchAutomatic
    Emergency Power OFFYes
    Transfer Time0 ns
    PhaseSingle Phase
    Application/UsageGovernment
    Application/UsageMilitary
    Application/UsageHealthcare
    Application/UsageMission Critical Equipment
    Application/UsageEducation
    Application/UsageIT Equipment
    Power Description
    Load Capacity (VA)3000 VA
    Load Capacity (Watt)2700 W
    Input Voltage120 V AC
    Output Voltage120 V AC
    Output Voltage110 V AC
    Output Voltage100 V AC
    Output Frequency60 Hz
    Waveform TypePure Sine Wave
    Surge Energy Rating190 J
    Input Power Factor0.99
    Output Power Factor0.9
    Display & Graphics
    DisplayLCD
    Management
    Network ManagementSNMP
    AlarmRemote Shutdown
    AlarmPower Failure
    AlarmUPS Fault
    AlarmOverload
    AlarmUPS StartUp
    AlarmLow Battery
    Controls/Indicators
    Status IndicatorsFront panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options
    Interfaces/Ports
    Serial PortYes
    USBYes
    Battery Information
    DC System Voltage96 V DC
    Battery CharacteristicsValve-regulated
    Battery ChemistryLead Acid
    Backup/Run Time (Full Load)5.70 Minute
    Backup/Run Time (Half Load)16.70 Minute
    Typical Battery Recharge Time3 Hour
    Hot SwappableYes
    Replaceable BatteryYes
    Environmental Conditions
    Minimum Operating Temperature32°F (0°C)
    Maximum Operating Temperature104°F (40°C)
    Storage Temperature32°F (0°C) - 104°F (40°C)
    Maximum Operating Elevation9842.52 ft
    Sound Emission52 dB
    Physical Characteristics
    Height13.6"
    Width8.4"
    Depth16.2"
    Form FactorTower
    Weight (Approximate)73.64 lb
    Miscellaneous
    Package Contents
  • SmartOnline SU3000XLCD 3000VA Tower UPS
  • USB cable
  • DB9 cable
  • Quick Start Guide
  • Certifications & Standards
    • UL1778
    • CSA
    • NOM
    • FCC Part 15
    Software IncludedPowerAlert Software
    Environmentally FriendlyYes
    Environmental CertificationRoHS
    Environmental CertificationREACH
    Country of OriginChina
    Warranty
    Limited Warranty2 Year
    Accessories:

    $ 3,094.42
    Quantity:
    Add
    Shipping Information
    Length 16.2"
    Width 8.4"
    Height 13.6"
    Weight 73.64 lb
    Quick Links
    Company Info
    ITConsultantsPR, Inc.
    245 Luchetti Industrial Park
    Rd #5 Km 26.2 STE 1
    Bayamon, PR
    00961
    USA

    Sign up now
    Connect With


    Call Us
    ITConsultantsPR, Inc., Information Technology Services, Bayamon, PR
    (787) 520-7121
    Copyright © 2024 ITConsultantsPR, Inc. All rights reserved.
    All other trademarks are the property of their respective owners.
    This website uses cookies to enhance your experience. By clicking "OK", or continuing to use this site, you agree to our use of cookies.